H.Stars Integrated Ice Storage Unit | Energy-Efficient Cooling and Ice Thermal Storage Solution

The H.Stars Integrated Ice Storage Unit is an energy-efficient HVAC solution designed to combine chiller cooling, ice production, thermal energy storage, and chilled water supply in one integrated system. It helps commercial and industrial facilities shift cooling demand away from peak electricity periods, improve energy management, and reduce operating costs.
Inquiry now
Product Detail

H.Stars Integrated Ice Storage Unit | Energy-Efficient Cooling and Ice Thermal Storage Solution

By producing and storing ice during off-peak hours, the system can release stored cooling capacity when demand is high. This makes the integrated ice storage solution particularly suitable for applications with significant daytime cooling loads or large differences between peak and off-peak electricity prices.

Ice Thermal Storage System Chiller


Integrated Cooling and Ice Storage in One System

Unlike conventional cooling systems that require separate chillers and ice storage equipment, the H.Stars Integrated Ice Storage Unit combines multiple functions into a compact and coordinated system. Depending on project requirements, the unit can provide chilled water for air conditioning while also operating in an ice-making mode for thermal energy storage.
The system can typically supply chilled water for HVAC applications while producing low-temperature water for ice storage. Intelligent controls automatically manage the operating modes according to cooling demand, electricity pricing, and system requirements.

Key Features of the H.Stars Integrated Ice Storage Unit

1. Peak Load Shifting and Energy Cost Reduction

The system stores cooling energy during off-peak periods and releases it during peak demand hours. This helps reduce peak electrical demand and can lower overall operating costs where time-of-use electricity pricing is available.

2. Integrated and Space-Saving Design

The integrated design combines cooling, ice-making, thermal storage, and control functions into a coordinated solution. Compared with traditional systems using multiple independent components, this can simplify system configuration and installation.

3. Flexible Cooling Operation

The unit can support different operating modes, including:
• Chilled water cooling mode
• Ice-making mode
• Ice storage and cooling release mode
• Automatic switching between operating conditions
This flexibility allows the system to adapt to changing cooling loads throughout the day.

4. Intelligent Automatic Control

An intelligent control system monitors operating conditions and manages the switching between cooling and ice storage modes. Automatic operation helps improve system efficiency, simplify management, and support stable long-term performance.

5. Reliable Thermal Storage Technology

The ice storage section is designed for reliable thermal energy storage and controlled cooling release. High-quality materials and optimized heat transfer design help ensure efficient ice formation and stable cooling performance.

6. Customized HVAC and Industrial Cooling Solutions

H.Stars can provide customized integrated ice storage solutions based on cooling capacity, operating temperatures, building load profiles, available installation space, and project requirements. The system can be applied to commercial HVAC projects as well as industrial cooling applications.

HVAC Ice Storage Solution



Applications

The H.Stars Integrated Ice Storage Unit is suitable for projects that require efficient cooling management and peak load reduction, including:
• Commercial buildings
• Office complexes
• Hotels and resorts
• Shopping centers
• Hospitals
• Data centers
• Industrial facilities
• Manufacturing plants
• District cooling systems

Why Choose an Integrated Ice Storage System?

As electricity demand and cooling loads continue to increase, thermal energy storage provides an effective way to improve HVAC system flexibility. An integrated ice storage system allows facilities to produce cooling during periods of lower electricity demand and use stored cooling when system loads are at their highest.
With integrated equipment design, intelligent control, and customized engineering support, the H.Stars Integrated Ice Storage Unit provides a practical solution for energy-efficient air conditioning and industrial cooling projects.
H.Stars Group offers customized HVAC and thermal energy storage solutions to meet different project requirements, helping customers improve cooling efficiency, optimize energy consumption, and achieve more flexible system operation.

Energy-Efficient Cooling System



Water-Cooled Scroll Ice Storage Chiller Specifications

Refrigerant: R410A Power Supply: 3φ, 380V, 50Hz


Unit Model

20STB-BV25WS4

20STB-BV50WD4

20STB-BV75WT4

20STB-BV100WF4

 

Air-Conditioning Operating Mode

Cooling Capacity kW

78

155

233

310

Power kW

16

33

49

65

 

Ice Storage Operating Mode

Cooling Capacity kW

46

92

138

184

Power kW

16

32

48

64

Refrigerant Charge kg

55

110

165

220

8–10 Hour Ice Storage Capacity kW

358

715

1073

1430

 

 

 

Cooling Side

Inlet/Outlet Pipe Size in

2"

2-1/2"

3"

4"

Water Flow Rate m³/h

16

32

48

65

Maximum Working Pressure Mpa

1.0

1.0

1.0

1.0

Water Pressure Drop kPa

42

46

52

65

 

Inlet/Outlet Connection Size in

2

2-1/2"

3"

4"

Service Side

Water Flow m³/h

15

31

46

62

Water Pressure Drop kPa

10

10

10

10

Unit Length    m

3.8

7.5

11.0

14.0

Unit Width  m

2.2

2.2

2.2

2.2

Unit Height m

2.4

2.4

2.4

2.4

Unit Net Weight kg

2000

4000

6000

8000

Unit operating weight kg

9000

18000

27000

36000

Note: 
1.Nominal Air-Conditioning Mode Reference: Evaporator inlet/outlet water temperature 12/7℃ , condenser inlet/outlet water temperature 30/35℃ , fouling factor 0.018 ㎡·℃ /kW. 
2.Nominal reference conditions for ice storage operation: Evaporation temperature -7℃ , condenser inlet/outlet water temperature 28/33℃ , fouling factor 0.018 ㎡·℃ C/kW. 
3.Chilled Water Temperature Range: 1–20℃ . 
4.Cooling Water Temperature Range: 15–40℃ . 
5.Specifications and dimensions may vary due to product improvements. The confirmed parameters and drawings at the time of order shall prevail.


Air-Cooled Scroll Ice Storage Chiller Specifications

Refrigerant: R410A Power Supply: 3φ, 380V, 50Hz

Unit Model

20STB- BV25AS4

20STB- BV50AD4

20STB- BV75AT4

20STB- BV100AF4

20STB- BV125AG4

20STB- BV150AH4

 

Air-Conditioning Operating Mode

Cooling CapacitykW

68

136

204

272

340

408

Power kW

20

40

60

80

100

120

 

Ice Storage Operating Mode

Cooling CapacitykW

40

80

120

160

200

240

Power kW

20

40

59

79

99

119

Refrigerant Charge kg

60

120

180

225

295

340

8–10 Hour Ice Storage Capacity kW

310

621

931

1241

1551

1862

 

Cooling Side

Air flow

ratex10^3m³/h

24.0

25.2

76.8

92.0

115.2

138.0

Fan input power kW

1.1

3.7

6.0

8.0

9.0

12.0

 

 

Service Side

Inlet/Outlet Connection Size in

2"

2-1/2"

3"

4"

4"

5"

Water Flow m³/h

15

30

45

61

76

91

Water Pressure Drop kPa

10

10

10

10

10

10

Unit Length    m

4.2

7.2

11.4

14.4

19.1

23.0

Unit Width m

2.2

2.2

2.2

2.2

2.2

2.2

Unit Height m

2.4

2.4

2.4

2.4

2.4

2.4

Unit Net Weight kg

2500

4800

7400

9500

12200

14300

Unit operating weight kg

9500

19000

29000

38000

47500

56700

Note: 
1.Nominal Air-Conditioning Mode Reference: Evaporator inlet/outlet water temperature 12/7℃ , fouling factor 0.018 ㎡·℃ /kW, ambient temperature 35℃ . 
2.Nominal reference conditions for ice storage operation: Evaporation temperature -7℃ , fouling factor 0.018 ㎡·℃ /kW, ambient temperature 29℃ . 
3.Chilled Water Temperature Range: 1–20℃ . 
4.Ambient Temperature Range: 5–43℃ . 
5.Specifications and dimensions may vary due to product improvements. The confirmed parameters and drawings at the time of order shall prevail.

FAQ

1. Can an integrated ice storage unit operate without ice storage?

Yes. Depending on the system configuration, the unit can provide chilled water directly to the cooling system without relying on stored ice. This allows the system to operate according to the actual cooling demand.


2. How does an ice storage system reduce energy costs?

The system can produce and store ice during off-peak electricity periods and release the stored cooling capacity during peak hours, helping reduce peak demand and optimize energy costs.


3. What chilled water temperatures can an integrated ice storage unit provide?

The required chilled water temperature depends on the application and system design. H.Stars can configure the refrigeration and heat exchange system according to the required supply temperature and cooling conditions.


contact experts
Contact Person: Candy Cai Mobile/WhatsApp: +86 13119505727 Tel: +86-20-62266755 Ext. 886 Fax: +86-20-82266081 Email: [email protected]
Related Products
H.Stars Open-type Compressor Chiller Open-Type Compressor Industrial Chiller
The H.Stars Open-Type Compressor Chiller is a high-performance industrial chiller designed to provide reliable, efficient, and stable cooling for demanding industrial applications. With a flexible open-type compressor configuration, the system is suitable for projects requiring customized cooling capacity, specialized temperature control, convenient maintenance, and long-term continuous operation.
Efficient Industrial Heating Solution up to 120°C Ultra-High-Temperature Hot Water Unit
The H.Stars Ultra-High-Temperature Hot Water Unit is an advanced industrial heat pump solution designed to provide high-temperature hot water for demanding heating and process applications. Using efficient heat pump technology, the system can produce hot water at temperatures of up to 120°C, helping industrial and commercial users reduce energy consumption and improve heating efficiency.
Ice Rink Dedicated Chiller H.Stars Ice Rink Dedicated Chiller | Reliable Cooling Solution for Ice Rink Applications
The H.Stars Ice Rink Dedicated Chiller is a specialized refrigeration solution designed to provide stable and efficient cooling for indoor and outdoor ice rinks. Developed for ice-making and ice surface maintenance applications, the system delivers reliable low-temperature cooling to help maintain consistent ice quality under changing operating conditions.
Air-Cooled Chiller with Free Cooling H.Stars Air-Cooled Chiller with Free Cooling | Energy-Efficient Cooling Solution
The H.Stars Air-Cooled Chiller with Free Cooling is an energy-efficient cooling solution designed to reduce mechanical refrigeration energy consumption by utilizing low outdoor ambient temperatures. By combining an air-cooled chiller with a free cooling system, the unit can automatically select the most suitable cooling mode according to ambient conditions and cooling demand.
modular scroll chiller suppliers China modular scroll type water chiller heat pump manufacturer
For cold storage, food processing, quick freezing and industrial cooling. The product is manufactured by adopting the combination of famous brand compressors and electronic control components. It is equipped with high-efficiency fin condenser and evaporator. The unit is controlled by microcomputer and equipped with various protection functions which is high reliability, and can exert the highest efficiency in the actual working conditions.
low temperature glycol chillers Industrial Low Temperature Glycol /Brine Chiller
H.Stars Industrial Low Temperature Glycol /Brine Chiller can be used for food processing, pharmaceutical, refrigeration and various industrial and commercial cooling systems with energy saving and high COP.

Copyright © 2015-2026 H.Stars (Guangzhou) Refrigerating Equipment Group Ltd.

/ Blog / Sitemap / XML / Privacy-policy