H.Stars Integrated Ice Storage Unit | Energy-Efficient Cooling and Ice Thermal Storage Solution
By producing and storing ice during off-peak hours, the system can release stored cooling capacity when demand is high. This makes the integrated ice storage solution particularly suitable for applications with significant daytime cooling loads or large differences between peak and off-peak electricity prices.
|
Unit Model |
20STB-BV25WS4 |
20STB-BV50WD4 |
20STB-BV75WT4 |
20STB-BV100WF4 |
|
|
Air-Conditioning Operating Mode |
Cooling Capacity kW |
78 |
155 |
233 |
310 |
|
Power kW |
16 |
33 |
49 |
65 |
|
|
Ice Storage Operating Mode |
Cooling Capacity kW |
46 |
92 |
138 |
184 |
|
Power kW |
16 |
32 |
48 |
64 |
|
|
Refrigerant Charge kg |
55 |
110 |
165 |
220 |
|
|
8–10 Hour Ice Storage Capacity kW |
358 |
715 |
1073 |
1430 |
|
|
Cooling Side |
Inlet/Outlet Pipe Size in |
2" |
2-1/2" |
3" |
4" |
|
Water Flow Rate m³/h |
16 |
32 |
48 |
65 |
|
|
Maximum Working Pressure Mpa |
1.0 |
1.0 |
1.0 |
1.0 |
|
|
Water Pressure Drop kPa |
42 |
46 |
52 |
65 |
|
|
|
Inlet/Outlet Connection Size in |
2 |
2-1/2" |
3" |
4" |
|
Service Side |
Water Flow m³/h |
15 |
31 |
46 |
62 |
|
Water Pressure Drop kPa |
10 |
10 |
10 |
10 |
|
|
Unit Length m |
3.8 |
7.5 |
11.0 |
14.0 |
|
|
Unit Width m |
2.2 |
2.2 |
2.2 |
2.2 |
|
|
Unit Height m |
2.4 |
2.4 |
2.4 |
2.4 |
|
|
Unit Net Weight kg |
2000 |
4000 |
6000 |
8000 |
|
|
Unit operating weight kg |
9000 |
18000 |
27000 |
36000 |
|
Note:
1.Nominal Air-Conditioning Mode Reference: Evaporator inlet/outlet water temperature 12/7℃ , condenser inlet/outlet water temperature 30/35℃ , fouling factor 0.018 ㎡·℃ /kW.
2.Nominal reference conditions for ice storage operation: Evaporation temperature -7℃ , condenser inlet/outlet water temperature 28/33℃ , fouling factor 0.018 ㎡·℃ C/kW.
3.Chilled Water Temperature Range: 1–20℃ .
4.Cooling Water Temperature Range: 15–40℃ .
5.Specifications and dimensions may vary due to product improvements. The confirmed parameters and drawings at the time of order shall prevail.
|
Unit Model |
20STB- BV25AS4 |
20STB- BV50AD4 |
20STB- BV75AT4 |
20STB- BV100AF4 |
20STB- BV125AG4 |
20STB- BV150AH4 |
|
|
Air-Conditioning Operating Mode |
Cooling CapacitykW |
68 |
136 |
204 |
272 |
340 |
408 |
|
Power kW |
20 |
40 |
60 |
80 |
100 |
120 |
|
|
Ice Storage Operating Mode |
Cooling CapacitykW |
40 |
80 |
120 |
160 |
200 |
240 |
|
Power kW |
20 |
40 |
59 |
79 |
99 |
119 |
|
|
Refrigerant Charge kg |
60 |
120 |
180 |
225 |
295 |
340 |
|
|
8–10 Hour Ice Storage Capacity kW |
310 |
621 |
931 |
1241 |
1551 |
1862 |
|
|
Cooling Side |
Air flow ratex10^3m³/h |
24.0 |
25.2 |
76.8 |
92.0 |
115.2 |
138.0 |
|
Fan input power kW |
1.1 |
3.7 |
6.0 |
8.0 |
9.0 |
12.0 |
|
|
Service Side |
Inlet/Outlet Connection Size in |
2" |
2-1/2" |
3" |
4" |
4" |
5" |
|
Water Flow m³/h |
15 |
30 |
45 |
61 |
76 |
91 |
|
|
Water Pressure Drop kPa |
10 |
10 |
10 |
10 |
10 |
10 |
|
|
Unit Length m |
4.2 |
7.2 |
11.4 |
14.4 |
19.1 |
23.0 |
|
|
Unit Width m |
2.2 |
2.2 |
2.2 |
2.2 |
2.2 |
2.2 |
|
|
Unit Height m |
2.4 |
2.4 |
2.4 |
2.4 |
2.4 |
2.4 |
|
|
Unit Net Weight kg |
2500 |
4800 |
7400 |
9500 |
12200 |
14300 |
|
|
Unit operating weight kg |
9500 |
19000 |
29000 |
38000 |
47500 |
56700 |
|