The Difference of Three Types Heat Exchanger in Hot Water unit
2020-10-26
In general, tube heat exchanger in hot water unit has long life span. Shell and tube heat exchanger structure: The shell and tube heat exchanger is composed of shell, heat transfer tube bundle, tube sheet, baffle plate (baffle plate), and tube box. The shell is mostly cylindrical with a tube bundle inside, and both ends of the tube bundle are fixed on the tube plate. There are two types of heat tr...
view more
-
How to do daily maintenance for air-cooled chillers | Hstarschiller.com
2020-11-10
Air-cooled chillers, as a kind of more efficient refrigeration equipment in chiller products, are widely used in the domestic industrial market and become necessary equipment for many industrial production. At the same time, although the air-cooled chiller is equipped with multiple protection devices, these are all to prevent the failure from directly damaging the unit. If the company wants to ens...
view more
-
The Role and Characteristics of Condenser in Refrigeration System
2020-11-16
The four major components of the refrigeration system are compressor, evaporator, condenser and throttling device. The role of the condenser in the refrigeration system is mainly to cool and liquefy the gaseous refrigerant in the high temperature and high pressure state discharged from the compressor, so as to meet the requirements of the circulating use of the refrigerant in the system. The selec...
view more
-
What is a plate and shell heat exchanger | Hstarschiller.com
2020-12-07
The plate and shell heat exchanger is composed of a plate bundle composed of a plate group and a shell. It is a plasma arc welded corrugated plate group placed in the shell instead of the heat exchange tube of the original shell and tube heat exchanger. The plate group is used as the heat exchanger of the heat transfer element. The two fluid media respectively flow through the plate side and the s...
view more
-
Tips for seasonal water chiller system shutdown in winter
2021-03-12
Introduction: Winter is coming, and the ambient temperature is about to drop below zero. This will cause great damage to the chillers, water pumps, cooling towers, terminals and other equipment. In order to ensure that chillers work normally during winter, the chiller has to survive in the low temperature environment, because it will cause a great loss to users if the unit is not maintained with p...
view more
-
Upgraded high-efficiency plate and shell heat exchanger advantages
2021-04-02
The plate and shell heat exchanger is composed of a plate bundle and a shell composed of a plate group. The corrugated plate group is put into the shell by plasma arc welding, instead of the heat exchange tube of the original shell and tube heat exchanger, with corrugated The plate group is used as the heat exchanger of the heat transfer element. The two fluid media respectively flow through the p...
view more
-
Energy Saving Chiller System with Heat Recovery Unit of 70℃ Hot Water
2021-04-13
The heat recovery chiller is a new type of energy recovery chiller. It has one more heat recovery device than conventional chillers,it is an economical chiller. It can produce hot water for free at the same time when making cold water. The hot water temperature can reach up to 70 degrees. It is very suitable for hotels, guesthouses and pharmaceuticals, electronic constant temperature and humidity ...
view more
-
90℃ dual source heat pump | Hstarschiller.com
2021-12-07
H.Stars Group has recently signed a contract with 90℃ dual source heat pump unit project for one of the famous automobile factory to replace the traditional boiler. Below are the features of high-efficiency 90-degree dual source heat pump: 1. Special design and customized size for easy installation. 2. Adopt the special compressor of Hanbell high temperature heat pump, with high compression ratio,...
view more
-
How to design a reliable artificial ice rink refrigeration system
2021-06-11
Nowadays, as the increasing economy of peoples life, more and more people are in need of ice rink . Therefore, many engineer company is worried about designing a best ice rink refrigeration system with reliability and energy efficient goal. Here are some best suggestions for you before you build an ice rink. Better take a look and it will help you save your time and money. 1. Refrigeration system ...
view more
-
Attention: Brine concentration will cause serious consequences to brine chiller
2021-06-24
Low-temperature brine chiller is also one of the more commonly used refrigeration equipment. Its refrigerant is the so-called brine solution, which has a low freezing point. It is especially suitable for medium and low temperature chillers to carry cold capacity. The temperature is generally required to be controlled below 0 ℃, which is usually used for the low temperature demand of some special p...
view more
-
What is the energy saving and cost saving cooling system for sand mill in printing ink factory
2021-07-15
The development of Chinese ink industry can be traced back to the beginning of the 20th century. Since the reform and opening up, the domestic ink market has developed rapidly, and inks have been widely used in various media such as paper, metal, glass, and plastic. In recent years, affected by the further advancement of environmental protection work, the price of some chemical raw materials has r...
view more
-
How to design a water chiller system with AHU for pharmaceutical factory workshop
2021-08-20
Nowadays, it’s become more and more aware of pharmaceutical enterprises to realize the significance of building an efficient and green to environment cooling system in the factory, because it can not only help the owner to save the running cost but also contribute to the society by reducing the emissions, especially for those developed countries . But how to design a simple but energy saving cooli...
view more
-
How to design a water cooled chiller for UHV electrode foil production line
2022-09-23
A proper water cooled chiller system for UHV electrode foil production line is very essential and important to the industry. However some HVAC engineers still have doubts on how to design a cooling system. Here we will bring a case reference for you. Project Overview This plan is designed for the aluminum foil production line one of the Western Electronic Technology Co., Ltd. The project is ...
view more
-
How to design the best Heat recovery water-cooled screw chiller for dairy industry
2021-11-03
Dairy industry production line has to adopt chiller for its dairy processing , however, it’s very important for the enterprise to select the right chiller ,especially the high efficiency with more energy saving after it’s installed. Heat recovery water cooled screw chiller has become more and more popular among those chillers. In order to avoid selection mistake , here is an good example for one o...
view more
-
How to design a best explosion proof industrial chiller for Chemical factories
2022-03-08
It’s common acknowledged that chemical factory is quite easy cause explosion if all the electrical products don’t handle well. Today we are going to share one of the cooling project with explosion proof chiller system to help you understand How to design a best explosion proof industrial chiller for Chemical factories. Project Overview This project is an industrial cooling project of Chemical Co.,...
view more
-
How to design heating system for a pharmaceutical factory dormitory building
2022-04-15
As we know that the simplest way to build heating system for hot water for dormitory is adopting boiler with coal burning ,which will cause CO2 increase for the earth. Here is the good example how to design the heating system with energy saving heat pumps to protect the environment. The project is the central air conditioning project and hot water project of a pharmaceutical factory dormitory buil...
view more
-
How to design the energy saving cooling system for factory production line and office building
2022-06-15
Project Overview This project is for one of the new factory buildings for one of the 500 fortune company of Dairy industry . The factory new workshop building area is about 17,000 square meters, with a total of 2 floors. H.Stars Group has helped this company to design the energy saving cooling system by adopting low-temperature chiller and low-ambient temperature air source heat pump unit Pr...
view more
-
How to choose the material of seawater heat exchanger for offshore platform
2023-02-24
1、 Introduction: With the implementation of the national strategy of developing the ocean, the use of petrochemical devices on my country's offshore platforms has developed rapidly. Seawater heat exchanger is an important equipment that is most widely used in offshore platform operations. The heat exchange status of the heat exchanger directly affects the smooth operation of the entire platform an...
view more