Basic requirements for structural design of low temperature heat exchanger
2020-09-09
Carbon steel and low-alloy steel heat exchangers (design temperature lower than -20℃), austenitic stainless steel heat exchangers (design temperature lower than -196℃) are low temperature heat exchangers, and the structural design should follow the following in principle. Material selection of low temperature heat exchanger: 1. Use temperature of plastic materials Polyvinyl chloride (PVC) -15℃~+80...
view more
-
The Difference of Three Types Heat Exchanger in Hot Water unit
2020-10-26
In general, tube heat exchanger in hot water unit has long life span. Shell and tube heat exchanger structure: The shell and tube heat exchanger is composed of shell, heat transfer tube bundle, tube sheet, baffle plate (baffle plate), and tube box. The shell is mostly cylindrical with a tube bundle inside, and both ends of the tube bundle are fixed on the tube plate. There are two types of heat tr...
view more
-
What is a plate and shell heat exchanger | Hstarschiller.com
2020-12-07
The plate and shell heat exchanger is composed of a plate bundle composed of a plate group and a shell. It is a plasma arc welded corrugated plate group placed in the shell instead of the heat exchange tube of the original shell and tube heat exchanger. The plate group is used as the heat exchanger of the heat transfer element. The two fluid media respectively flow through the plate side and the s...
view more
-
Upgraded high-efficiency plate and shell heat exchanger advantages
2021-04-02
The plate and shell heat exchanger is composed of a plate bundle and a shell composed of a plate group. The corrugated plate group is put into the shell by plasma arc welding, instead of the heat exchange tube of the original shell and tube heat exchanger, with corrugated The plate group is used as the heat exchanger of the heat transfer element. The two fluid media respectively flow through the p...
view more
-
Energy Saving Chiller System with Heat Recovery Unit of 70℃ Hot Water
2021-04-13
The heat recovery chiller is a new type of energy recovery chiller. It has one more heat recovery device than conventional chillers,it is an economical chiller. It can produce hot water for free at the same time when making cold water. The hot water temperature can reach up to 70 degrees. It is very suitable for hotels, guesthouses and pharmaceuticals, electronic constant temperature and humidity ...
view more
-
How to select and design with industrial low temperature chiller unit
2021-04-20
Recently, when communicating with some customers, we found that we were not very clear about the type selection and system design of low temperature units. However, the low temperature chiller is a very important equipment for chemical industry, raw material pharmaceutical factory and other enterprises, and it is also the place with the largest energy consumption for such enterprises. Therefore, h...
view more
-
How to reduce the initial investment and operation cost of low-temperature chiller for chemical plants
2021-04-23
Nowadays, chemical plants always consider how to reduce the initial investment and operation cost when they need to install a low-temperature chiller system for the factory. Because low temperature refrigeration unit is a very important equipment in chemical plant, which plays an important role in safety production. The initial investment of low-temperature refrigeration unit is large, and i...
view more
-
90℃ dual source heat pump | Hstarschiller.com
2021-12-07
H.Stars Group has recently signed a contract with 90℃ dual source heat pump unit project for one of the famous automobile factory to replace the traditional boiler. Below are the features of high-efficiency 90-degree dual source heat pump: 1. Special design and customized size for easy installation. 2. Adopt the special compressor of Hanbell high temperature heat pump, with high compression ratio,...
view more
-
How to measure brine concentration for the brine chiller
2021-05-21
How to measure brine concentration for the brine chiller ? Saltwater brine chillers are also one of the more commonly used refrigeration equipment. Its refrigerant is the so-called brine solution, which has a low freezing point. It is especially suitable for medium and low temperature chillers to carry cold capacity. The temperature is generally required to be controlled at 0 Below ℃, it is usuall...
view more
-
How does the chiller manufacturer guarantee the quality of the chiller
2021-06-04
Before manufacturing water chillers, chiller manufacturers will design considerations for the industry, cooling capacity, structure, etc. of a product, and consider the actual use environment to make certain optimizations when designing and assembling. . So how does the industrial water chiller manufacturer ensure the quality of the water chiller? To ensure the quality of chiller products, it is n...
view more
-
Attention: Brine concentration will cause serious consequences to brine chiller
2021-06-24
Low-temperature brine chiller is also one of the more commonly used refrigeration equipment. Its refrigerant is the so-called brine solution, which has a low freezing point. It is especially suitable for medium and low temperature chillers to carry cold capacity. The temperature is generally required to be controlled below 0 ℃, which is usually used for the low temperature demand of some special p...
view more
-
How to design the best Heat recovery water-cooled screw chiller for dairy industry
2021-11-03
Dairy industry production line has to adopt chiller for its dairy processing , however, it’s very important for the enterprise to select the right chiller ,especially the high efficiency with more energy saving after it’s installed. Heat recovery water cooled screw chiller has become more and more popular among those chillers. In order to avoid selection mistake , here is an good example for one o...
view more
-
H.Stars Group developed a series of new refrigerant equipment with low GWP for carbon reduction and energy saving in 2021
2021-12-07
According to the news on December 23, Chemours announced that from January 1, 2020, they will stop supplying high-GWP R404A and R507A refrigerants to the European Union. At the time of this announcement, Europe is preparing to implement a ban on high-GWP refrigerants in accordance with the European F-gas regulations (517/2014) implemented on January 1. According to the European F-gas phase-out sch...
view more
-
How to design a best explosion proof industrial chiller for Chemical factories
2022-03-08
It’s common acknowledged that chemical factory is quite easy cause explosion if all the electrical products don’t handle well. Today we are going to share one of the cooling project with explosion proof chiller system to help you understand How to design a best explosion proof industrial chiller for Chemical factories. Project Overview This project is an industrial cooling project of Chemical Co.,...
view more
-
How to produce best quality of Explosion-proof Evaporative Chiller
2022-03-18
What is the explosion -proof evaporative chiller? And how to produce a best qualtity of explosion proof Water Cooled Chiller Low Temperature Chiller? H.Stars Group shall inform you all the details as below. In industries that need chillers to operate in dangerous conditions, explosion-proof chillers are the solution,because explosion-proof chillers have a reinforced design to protect the chiller’s...
view more
-
How to design heating system for a pharmaceutical factory dormitory building
2022-04-15
As we know that the simplest way to build heating system for hot water for dormitory is adopting boiler with coal burning ,which will cause CO2 increase for the earth. Here is the good example how to design the heating system with energy saving heat pumps to protect the environment. The project is the central air conditioning project and hot water project of a pharmaceutical factory dormitory buil...
view more
-
How to design the energy saving cooling system for factory production line and office building
2022-06-15
Project Overview This project is for one of the new factory buildings for one of the 500 fortune company of Dairy industry . The factory new workshop building area is about 17,000 square meters, with a total of 2 floors. H.Stars Group has helped this company to design the energy saving cooling system by adopting low-temperature chiller and low-ambient temperature air source heat pump unit Pr...
view more
-
How to choose the material of seawater heat exchanger for offshore platform
2023-02-24
1、 Introduction: With the implementation of the national strategy of developing the ocean, the use of petrochemical devices on my country's offshore platforms has developed rapidly. Seawater heat exchanger is an important equipment that is most widely used in offshore platform operations. The heat exchange status of the heat exchanger directly affects the smooth operation of the entire platform an...
view more