Choosing a network monitoring industrial water cooled Chiller from HStars
2019-02-21
Choosing a network monitoring industrial water cooled Chiller from HStars The single-chip controller of the HStars scroll typr chiller can customize the network monitoring function. The specific functions are as follows: 1.Industrial water cooled chiller networked monitoring the operational items-- Start command, stop command, reset command, cancel preheat, open external circulation pump, s...
view more
-
Pharmaceutical Factories, by Using These Ways, Can Clean the Air Conditioning System to Save 40% of the Operating Costs.
2019-05-21
Pharmaceutical factories need to meet the relevant requirements of GMP in the production process, and the temperature, humidity and cleanliness must be controlled within a certain range. Under normal circumstances, when there is no special requirement, the temperature should be controlled between 18 ° C ~ 26 ° C; the relative humidity is controlled at 45% ~ 65%. The clean area of pharmaceutical fa...
view more
-
The three major drawbacks of the refrigeration equipment industry urgently need to be solved
2019-05-30
Refrigeration equipment is now widely used in various fields, and different industry requirements for equipment specifications are also different. With the expansion of various industries, the requirements and goals for refrigeration equipment are higher and higher. From the current situation, China's refrigeration industry still has many shortcomings, and its most obvious performance is the follo...
view more
-
The Reason Why the Temperature of Condensers of Water Cooled Chillers are Abnormally High
2019-06-28
Why are the temperature of condensers of water cooled chiller are abnormally high? The water-cooled condenser we mention here is mainly used in water-cooled chillers. Its function is to use the high-temperature refrigerant vapor condenser discharged from the compressor as a liquid refrigerant, which is an important part of the refrigeration system to release heat to the surrounding envir...
view more
-
Analysis of 10 major failure phenomena commonly seen in refrigeration equipment maintenance
2019-07-05
1. The exhaust gas temperature of the refrigeration system is too low: The low exhaust pressure is mainly caused by the small or even stop flow of the refrigerant in the refrigeration system. The exhaust pressure is too low, although the phenomenon is manifested at the high pressure end, but the cause is mostly caused by the low pressure end. Common reasons for low exhaust pressure: 1) T...
view more
-
The Solutions of Common Low Pressure for Chillers
2019-07-26
There are many factors that cause low-pressure failure of cold water (freezer) machines, and we only list some of them today. It can be roughly divided into the following categories (from easy to difficult sequence) system leakage, system blockage, and evaporator blockage. Important: The "Reset button" on the pressure controller must be pressed after each fault point has been processed. Common low...
view more
-
H.Stars High precision chiller can control temperature within 0.1℃
2019-09-09
1. Some special production processes such as: testing, precision material testing, precision instrument cooling water system, etc., need to ensure that the circulating cooling water inlet water constant temperature or high precision, so that the data or product performance is stable. 2. Water for food and medicine must ensure the temperature of the mixing water to ensure the stability of...
view more
-
H.Stars Group has launched the first batch of catalogs with 9 different types
2020-03-25
H.Stars Group has launched the first batch of catalogs with 9 different types. For more details or soft copy of our catalogs, welcome to contact us sales@hstars.com.cn . After launching the first batch of 9 new catalogs, H.Stars Group has been informed by clients overseas that they start to understand our products more. The first batch of catalogs is mainly for medium and large centrifugal and scr...
view more
-
Meet in Chongqing,Meet in Refrigeration Exhibition | Hstarschiller.com
2020-09-03
The 31st International Exhibition on Refrigeration, Air Conditioning, Heating, Ventilation and Food Frozen Exhibition (abbreviated as China Refrigeration Expo 2020) will be held at Chongqing International Expo Center from August 19 to 21, 2020. At that time, Guangzhou United A/C&R Co., Ltd. will bring its self-developed all-stainless steel products, titanium tube evaporator, and H.Stars ...
view more
-
H.Stars Group industrial water screw chillers are ranked top 75 of the world tire industry
2020-09-03
Anhui Jiatong Tire Co., Ltd. is a large-scale tire manufacturing enterprise solely established by Jiatong Group Singapore Jiatong Tire Co., Ltd. Among the 55 major tire manufacturers in China, Anhui Jiatong ranks first in tire production and sales; in the world tire industry The Top 75 ranked 21st in total sales in 2001. The chilled water supply system mainly provides 7-12℃ chilled...
view more
-
Basic requirements for structural design of low temperature heat exchanger
2020-09-09
Carbon steel and low-alloy steel heat exchangers (design temperature lower than -20℃), austenitic stainless steel heat exchangers (design temperature lower than -196℃) are low temperature heat exchangers, and the structural design should follow the following in principle. Material selection of low temperature heat exchanger: 1. Use temperature of plastic materials Polyvinyl chloride (PVC) -15℃~+80...
view more
-
How to do daily maintenance for air-cooled chillers | Hstarschiller.com
2020-11-10
Air-cooled chillers, as a kind of more efficient refrigeration equipment in chiller products, are widely used in the domestic industrial market and become necessary equipment for many industrial production. At the same time, although the air-cooled chiller is equipped with multiple protection devices, these are all to prevent the failure from directly damaging the unit. If the company wants to ens...
view more
-
The Role and Characteristics of Condenser in Refrigeration System
2020-11-16
The four major components of the refrigeration system are compressor, evaporator, condenser and throttling device. The role of the condenser in the refrigeration system is mainly to cool and liquefy the gaseous refrigerant in the high temperature and high pressure state discharged from the compressor, so as to meet the requirements of the circulating use of the refrigerant in the system. The selec...
view more
-
Tips for seasonal water chiller system shutdown in winter
2021-03-12
Introduction: Winter is coming, and the ambient temperature is about to drop below zero. This will cause great damage to the chillers, water pumps, cooling towers, terminals and other equipment. In order to ensure that chillers work normally during winter, the chiller has to survive in the low temperature environment, because it will cause a great loss to users if the unit is not maintained with p...
view more
-
Application of water chiller in concrete mixing
2021-03-26
In 2004, the Ministry of Construction issued a document that chilled water must be used in the concrete mixer projects such as subways, bridges, and dams. The chilled water varies according to the outdoor temperature across the country, and the general temperature is 2℃-7℃ . H.Stars Group has not been involved in this market before, and customers know little about chillers, so ordinary customers b...
view more
-
Energy Saving Chiller System with Heat Recovery Unit of 70℃ Hot Water
2021-04-13
The heat recovery chiller is a new type of energy recovery chiller. It has one more heat recovery device than conventional chillers,it is an economical chiller. It can produce hot water for free at the same time when making cold water. The hot water temperature can reach up to 70 degrees. It is very suitable for hotels, guesthouses and pharmaceuticals, electronic constant temperature and humidity ...
view more
-
How to design a reliable artificial ice rink refrigeration system
2021-06-11
Nowadays, as the increasing economy of peoples life, more and more people are in need of ice rink . Therefore, many engineer company is worried about designing a best ice rink refrigeration system with reliability and energy efficient goal. Here are some best suggestions for you before you build an ice rink. Better take a look and it will help you save your time and money. 1. Refrigeration system ...
view more
-
Attention: Brine concentration will cause serious consequences to brine chiller
2021-06-24
Low-temperature brine chiller is also one of the more commonly used refrigeration equipment. Its refrigerant is the so-called brine solution, which has a low freezing point. It is especially suitable for medium and low temperature chillers to carry cold capacity. The temperature is generally required to be controlled below 0 ℃, which is usually used for the low temperature demand of some special p...
view more