What's the difference between condenser and cooler?
2018-10-25
Today both Condenser and Cooler are very important heat exchanging components in commmercial or industrial refrigeration equipments, which are widely applied in many fields. Lots of customers who look for UAR for model selection are curious about the difference between Condenser and Cooler. So let’s make a brief introduction. 1)Phase change doesn’t occur in Cooler while it happens in Condenser. Ge...
view more
-
Pharmaceutical Factories, by Using These Ways, Can Clean the Air Conditioning System to Save 40% of the Operating Costs.
2019-05-21
Pharmaceutical factories need to meet the relevant requirements of GMP in the production process, and the temperature, humidity and cleanliness must be controlled within a certain range. Under normal circumstances, when there is no special requirement, the temperature should be controlled between 18 ° C ~ 26 ° C; the relative humidity is controlled at 45% ~ 65%. The clean area of pharmaceutical fa...
view more
-
The three major drawbacks of the refrigeration equipment industry urgently need to be solved
2019-05-30
Refrigeration equipment is now widely used in various fields, and different industry requirements for equipment specifications are also different. With the expansion of various industries, the requirements and goals for refrigeration equipment are higher and higher. From the current situation, China's refrigeration industry still has many shortcomings, and its most obvious performance is the follo...
view more
-
The Reason Why the Temperature of Condensers of Water Cooled Chillers are Abnormally High
2019-06-28
Why are the temperature of condensers of water cooled chiller are abnormally high? The water-cooled condenser we mention here is mainly used in water-cooled chillers. Its function is to use the high-temperature refrigerant vapor condenser discharged from the compressor as a liquid refrigerant, which is an important part of the refrigeration system to release heat to the surrounding envir...
view more
-
Analysis of 10 major failure phenomena commonly seen in refrigeration equipment maintenance
2019-07-05
1. The exhaust gas temperature of the refrigeration system is too low: The low exhaust pressure is mainly caused by the small or even stop flow of the refrigerant in the refrigeration system. The exhaust pressure is too low, although the phenomenon is manifested at the high pressure end, but the cause is mostly caused by the low pressure end. Common reasons for low exhaust pressure: 1) T...
view more
-
The Solutions of Common Low Pressure for Chillers
2019-07-26
There are many factors that cause low-pressure failure of cold water (freezer) machines, and we only list some of them today. It can be roughly divided into the following categories (from easy to difficult sequence) system leakage, system blockage, and evaporator blockage. Important: The "Reset button" on the pressure controller must be pressed after each fault point has been processed. Common low...
view more
-
The Reason That More and More People Choose Magnetic Oil Free Centrifugal Chiller
2019-07-30
With the rapid development of the times and economy, energy conservation and environmental protection and energy conservation and emission reduction have become an indispensable link. For a long time, the problems of “high energy consumption and secondary pollution” of central air-conditioning have brought great burdens to various industries. In the process of product operation, oil pollution, gre...
view more
-
Magnetic Oil Free Centrifugal Chiller Advantages
2019-08-26
With the rapid development of the times and economy, energy conservation, environmental protection, and emission reduction have become an indispensable new era mission. For a long time, the problems of “high energy consumption and secondary pollution” of central air-conditioning have brought great burdens to various industries. In the process of product operation, oil pollution, greenhouse ef...
view more
-
How can pharmaceutical air conditioning systems reduce operating costs by 40%
2019-08-30
Pharmaceutical factories need to meet GMP requirements in the production process, and the temperature, humidity and cleanliness should be controlled within a certain range. Under general circumstances, the temperature should be controlled at 18℃~26℃, the relative humidity should be controlled at 45%~65%, the pharmaceutical factory clean area is divided into ABCD level. The C and D level of the wor...
view more
-
H.Stars High precision chiller can control temperature within 0.1℃
2019-09-09
1. Some special production processes such as: testing, precision material testing, precision instrument cooling water system, etc., need to ensure that the circulating cooling water inlet water constant temperature or high precision, so that the data or product performance is stable. 2. Water for food and medicine must ensure the temperature of the mixing water to ensure the stability of...
view more
-
Magnetic Bearing Centrifugal Chiller Units
2020-04-30
Magnetic Bearing Centrifugal Chiller installed for one of the commercial building This is a central air-conditioning project for the Industrial bank commercial building. The office has a total air-conditioning area of 8,000 square meters and other supporting areas of 2000 square meters. Device configuration instructions of Magnetic Bearing Centrifugal Chiller Units This project has selected two un...
view more
-
High efficient evaporative cooling technology for refrigeration industry
2020-07-20
After years of practical exploration in the refrigeration industry, the increasing maturity of evaporative cooling technology has provided new ideas for improving the energy efficiency of chillers. Evaporative condensation technology is efficient, energy-saving and green. By reducing the condensation temperature, the energy efficiency of H.Stars chillers is increased by about 20% More and more use...
view more
-
H.Stars ±0.1℃ high-precision chiller for Laboratory of the university
2020-09-03
Project Background The Synchrotron Radiation Laboratory of the University of Science and Technology of China has built China's first dedicated synchrotron radiation source mainly based on vacuum ultraviolet and soft X-rays. To ensure the reliability and stability of the light source, it is necessary to provide stable constant-temperature cooling water in the device. The temperature should be contr...
view more
-
Basic requirements for structural design of low temperature heat exchanger
2020-09-09
Carbon steel and low-alloy steel heat exchangers (design temperature lower than -20℃), austenitic stainless steel heat exchangers (design temperature lower than -196℃) are low temperature heat exchangers, and the structural design should follow the following in principle. Material selection of low temperature heat exchanger: 1. Use temperature of plastic materials Polyvinyl chloride (PVC) -15℃~+80...
view more
-
Comparison Between Magnetic Centrifugal Chiller with Screw Chiller Difference Point and Advantage
2024-04-11
It is understood that the magnetic bearing chiller is a new type of centrifuge equipment appearing in the international market. Compare to screw chillerIts main characteristics are fast speed, low noise, energy saving, intelligent management, in line with the trend of green development, and the magnetic levitation technology is in the world's leading level. Magnetic levitation compressor . bearing...
view more
-
The Role and Characteristics of Condenser in Refrigeration System
2020-11-16
The four major components of the refrigeration system are compressor, evaporator, condenser and throttling device. The role of the condenser in the refrigeration system is mainly to cool and liquefy the gaseous refrigerant in the high temperature and high pressure state discharged from the compressor, so as to meet the requirements of the circulating use of the refrigerant in the system. The selec...
view more
-
H.Stars Screw Chiller Cools Rubber Seals and Reduces Electricity Bills
2020-12-18
In the production process of rubber and plastic seals and special rubber products, 15℃ constant temperature water is required to cool the rubber mixing process, so that the semi-finished product shape is fixed and instantly formed. If accurate low-temperature water cooling is not provided, the output and quality of the product will be seriously affected . At this time, a rubber-plastic screw chill...
view more
-
Tips for seasonal water chiller system shutdown in winter
2021-03-12
Introduction: Winter is coming, and the ambient temperature is about to drop below zero. This will cause great damage to the chillers, water pumps, cooling towers, terminals and other equipment. In order to ensure that chillers work normally during winter, the chiller has to survive in the low temperature environment, because it will cause a great loss to users if the unit is not maintained with p...
view more