How to descale the water-cooled condenser
2024-04-11
How does the chiller descale the water-cooled condenser? Many refrigeration units adpot water-cooled cooling system. The inner wall of the water-cooled condenser is easy to scale. These scales will affect the heat exchange effect, resulting in an increase the condensing temperature, which will badly lower cooling capacity and increased unit power consumption. Water-cooled condensers should be regu...
view more
-
How to maintain the radiator
2019-04-19
How to maintain the radiator First, check the radiator interface for leaks During the heating period, the surface temperature of the radiator is high, so there will be a phenomenon of thermal expansion and contraction, especially at the pipe joint, which is the main point of water leakage. Once the heating is stopped, the interface is loose, which will cause water leakage. Therefore,...
view more
-
How can pharmaceutical air conditioning systems reduce operating costs by 40%
2019-08-30
Pharmaceutical factories need to meet GMP requirements in the production process, and the temperature, humidity and cleanliness should be controlled within a certain range. Under general circumstances, the temperature should be controlled at 18℃~26℃, the relative humidity should be controlled at 45%~65%, the pharmaceutical factory clean area is divided into ABCD level. The C and D level of the wor...
view more
-
How to design a best purification workshop for edible fungus factory
2022-10-14
A clean room must be built for the industrialization of edible fungi. The clean rooms that need to be built include: laboratory, pre-cooling room, cooling room, and inoculation room. In addition to conforming to the basic specifications of the clean room, the clean room for edible mushroom production should also incorporate the concept and production process of edible mushroom production into the ...
view more
-
The Cost of Cooling Towers in Industrial Refrigeration
2023-12-06
Introduction: Cooling towers are a fundamental component of industrial refrigeration systems, but understanding the various costs associated with them is crucial for businesses considering their implementation. In this article, we will delve into the costs of cooling towers in industrial refrigeration and provide insights for potential buyers of refrigeration equipment. 1. Initial Purchase and Ins...
view more
-
Cleanroom Design Calculations – Unveiling the Secrets of Air Supply Calculations
2024-01-16
The calculation of air supply in a cleanroom differs from that of a general HVAC system. HVAC systems determine air supply based on calculated thermal and humidity loads, considering an economical air supply temperature difference to eliminate excess heat and moisture. In contrast, cleanroom air supply is generally calculated independent of thermal and humidity loads. Instead, it is based on the r...
view more