Indoor Artificial Ice Rink Refrigeration System Design And Selection
2021-03-11
Indoor Artificial Ice Rink Refrigeration System Design And Selection 1.Refrigeration System Features The refrigeration system of indoor ice skating rink usually adopts two refrigeration methods: direct expansion and indirect cooling. Direct expansion adopts "Hstars" brand condensing unit; indirect cooling adopts "Hstars" brand screw type low-temperature chiller, Glycol is used as a refrigerant to ...
view more
-
Dry Type and Flooded Type evaporator structure, principle, difference and advantages and disadvantages
2023-06-12
As we all know, the four major components of the refrigeration system are: compressor, evaporator, condenser, and throttling device. Among them, the type and characteristics of the compressor as the heart of the refrigeration system are more well known than the other three components. In addition, the evaporator is another key component. Do you know about the type and characteristics of the evapor...
view more
-
UNITED (GUANGZHOU) A / C & R CO.LTD. Muestra Fuerza de Tecnología Avanzada con Nuevos Intercambiadores de Calor en Exposición de Refrigeración China
2019-04-19
El 9 de abril de 2019, UNITED (GUANGZHOU) A / C & R CO.LTD. participó en la 30ª Exposición de Refrigeración de China, llevándose la intercambiador de calor para unidades de tipo spray y la intercambiador de calo...
view more
-
The difference between square type crossflow closed circuit cooling tower and traditional open cooling tower
2019-05-08
H.Stars Group water cooled chiller unit always need to adopt cooling tower to supply water to the cooling system . Hence, H.Stars has summarizes the difference between square type cross flow closed circuit cooling tower and traditional open cooling tower. The cooling water of the open cooling tower is directly contact with the air for heat exchange in the packing process, so the purity of the...
view more
-
Square Type Contra-flow closed Circuit Cooling Tower Working Principle
2019-05-14
Regarding to water cooled chiller working system, normally it needs to adopt water cooled chiller, cooling tower, water pump or tank etc. To familiar with H.Stars Group water cooled chiller system, here we are introducing you the working principle of square type contra-flow closed circuit cooling towers first. The working fluid (water, oil or other liquid) flows in the coil clock, ...
view more
-
The Solution of Cold Water of Concrete Mixing Station
2022-12-16
1.Background of the project Temperature-controlled concrete is required for large-scale pouring of large hydro power dams, nuclear power, high-speed iron, and high-rise building foundations. During the concrete mixing process, the internal volume of the concrete hydration heat increases, especially the heat generated by the stirring under high temperature conditions is higher. In the subsequent cu...
view more
-
How to find the right Explosion-proof chillers for industrial process cooling
2019-11-15
Introduction of explosion-proof chiller: International Industries have demanded a lot from their HVAC machines. Some of equipment might be susceptible to explosions inside and outside their circuitry. Getting an explosion-proof chiller is essential for many industrial environments. However ,very few factory can manufacture explosion-proof chillers with mature technology and ski...
view more
-
H.Stars Group has launched the first batch of catalogs with 9 different types
2020-03-25
H.Stars Group has launched the first batch of catalogs with 9 different types. For more details or soft copy of our catalogs, welcome to contact us sales@hstars.com.cn . After launching the first batch of 9 new catalogs, H.Stars Group has been informed by clients overseas that they start to understand our products more. The first batch of catalogs is mainly for medium and large centrifugal and scr...
view more
-
Basic requirements for structural design of low temperature heat exchanger
2020-09-09
Carbon steel and low-alloy steel heat exchangers (design temperature lower than -20℃), austenitic stainless steel heat exchangers (design temperature lower than -196℃) are low temperature heat exchangers, and the structural design should follow the following in principle. Material selection of low temperature heat exchanger: 1. Use temperature of plastic materials Polyvinyl chloride (PVC) -15℃~+80...
view more
-
How to select and design with industrial low temperature chiller unit
2021-04-20
Recently, when communicating with some customers, we found that we were not very clear about the type selection and system design of low temperature units. However, the low temperature chiller is a very important equipment for chemical industry, raw material pharmaceutical factory and other enterprises, and it is also the place with the largest energy consumption for such enterprises. Therefore, h...
view more
-
How to reduce the initial investment and operation cost of low-temperature chiller for chemical plants
2021-04-23
Nowadays, chemical plants always consider how to reduce the initial investment and operation cost when they need to install a low-temperature chiller system for the factory. Because low temperature refrigeration unit is a very important equipment in chemical plant, which plays an important role in safety production. The initial investment of low-temperature refrigeration unit is large, and i...
view more
-
How to measure brine concentration for the brine chiller
2021-05-21
How to measure brine concentration for the brine chiller ? Saltwater brine chillers are also one of the more commonly used refrigeration equipment. Its refrigerant is the so-called brine solution, which has a low freezing point. It is especially suitable for medium and low temperature chillers to carry cold capacity. The temperature is generally required to be controlled at 0 Below ℃, it is usuall...
view more
-
How does the chiller manufacturer guarantee the quality of the chiller
2021-06-04
Before manufacturing water chillers, chiller manufacturers will design considerations for the industry, cooling capacity, structure, etc. of a product, and consider the actual use environment to make certain optimizations when designing and assembling. . So how does the industrial water chiller manufacturer ensure the quality of the water chiller? To ensure the quality of chiller products, it is n...
view more
-
Attention: Brine concentration will cause serious consequences to brine chiller
2021-06-24
Low-temperature brine chiller is also one of the more commonly used refrigeration equipment. Its refrigerant is the so-called brine solution, which has a low freezing point. It is especially suitable for medium and low temperature chillers to carry cold capacity. The temperature is generally required to be controlled below 0 ℃, which is usually used for the low temperature demand of some special p...
view more
-
H.Stars Group developed a series of new refrigerant equipment with low GWP for carbon reduction and energy saving in 2021
2021-12-07
According to the news on December 23, Chemours announced that from January 1, 2020, they will stop supplying high-GWP R404A and R507A refrigerants to the European Union. At the time of this announcement, Europe is preparing to implement a ban on high-GWP refrigerants in accordance with the European F-gas regulations (517/2014) implemented on January 1. According to the European F-gas phase-out sch...
view more
-
How to design cooling system for commercial office building to reduce the emission of carbon dioxide
2022-02-15
First of all we need to understand what is meaning by "carbon dioxide " here. Generally speaking, carbon dioxide emissions refer to the emissions of greenhouse gases such as carbon dioxide and methane. Carbon reduction action is to reduce greenhouse gas emissions, thereby reducing the greenhouse effect. If too much greenhouse gas emissions cause the earth's average temperature to be too high...
view more
-
How to design a best explosion proof industrial chiller for Chemical factories
2022-03-08
It’s common acknowledged that chemical factory is quite easy cause explosion if all the electrical products don’t handle well. Today we are going to share one of the cooling project with explosion proof chiller system to help you understand How to design a best explosion proof industrial chiller for Chemical factories. Project Overview This project is an industrial cooling project of Chemical Co.,...
view more
-
How to produce best quality of Explosion-proof Evaporative Chiller
2022-03-18
What is the explosion -proof evaporative chiller? And how to produce a best qualtity of explosion proof Water Cooled Chiller Low Temperature Chiller? H.Stars Group shall inform you all the details as below. In industries that need chillers to operate in dangerous conditions, explosion-proof chillers are the solution,because explosion-proof chillers have a reinforced design to protect the chiller’s...
view more