The Solution of Food and Beverage Workshop Ice Water System
2019-09-04
Ⅰ.Demand Situation Food and beverage workshop ice water system engineering. The ice water system mainly meets the requirements of ice water on the production line. The required ice water temperature has two, one is 5 degrees ice water; the other is -5 degrees. Ⅱ. Load Calculation 1.5 degrees ice water total cooling capacity is 1500KW 2.-5 degrees ice water total cooling capacity 750KW 3.12 de...
view more
-
How can pharmaceutical air conditioning systems reduce operating costs by 40%
2019-08-30
Pharmaceutical factories need to meet GMP requirements in the production process, and the temperature, humidity and cleanliness should be controlled within a certain range. Under general circumstances, the temperature should be controlled at 18℃~26℃, the relative humidity should be controlled at 45%~65%, the pharmaceutical factory clean area is divided into ABCD level. The C and D level of the wor...
view more
-
How to help pharmaceutical factories to save electricity on HVACR system
2019-08-30
The raw material medicine is mainly produced by raw material fermentation or chemical synthesis. No matter which production process needs to be carried out at a relatively stable low temperature. Different medicines require different temperatures, such as antibiotic raw materials need to be maintained at around 25 °C during fermentation, other chemical raw materials are produced at tempe...
view more
-
Magnetic Oil Free Centrifugal Chiller Advantages
2019-08-26
With the rapid development of the times and economy, energy conservation, environmental protection, and emission reduction have become an indispensable new era mission. For a long time, the problems of “high energy consumption and secondary pollution” of central air-conditioning have brought great burdens to various industries. In the process of product operation, oil pollution, greenhouse ef...
view more
-
The Reason That More and More People Choose Magnetic Oil Free Centrifugal Chiller
2019-07-30
With the rapid development of the times and economy, energy conservation and environmental protection and energy conservation and emission reduction have become an indispensable link. For a long time, the problems of “high energy consumption and secondary pollution” of central air-conditioning have brought great burdens to various industries. In the process of product operation, oil pollution, gre...
view more
-
The Solutions of Common Low Pressure for Chillers
2019-07-26
There are many factors that cause low-pressure failure of cold water (freezer) machines, and we only list some of them today. It can be roughly divided into the following categories (from easy to difficult sequence) system leakage, system blockage, and evaporator blockage. Important: The "Reset button" on the pressure controller must be pressed after each fault point has been processed. Common low...
view more
-
Analysis of 10 major failure phenomena commonly seen in refrigeration equipment maintenance
2019-07-05
1. The exhaust gas temperature of the refrigeration system is too low: The low exhaust pressure is mainly caused by the small or even stop flow of the refrigerant in the refrigeration system. The exhaust pressure is too low, although the phenomenon is manifested at the high pressure end, but the cause is mostly caused by the low pressure end. Common reasons for low exhaust pressure: 1) T...
view more
-
The Reason Why the Temperature of Condensers of Water Cooled Chillers are Abnormally High
2019-06-28
Why are the temperature of condensers of water cooled chiller are abnormally high? The water-cooled condenser we mention here is mainly used in water-cooled chillers. Its function is to use the high-temperature refrigerant vapor condenser discharged from the compressor as a liquid refrigerant, which is an important part of the refrigeration system to release heat to the surrounding envir...
view more
-
Summary of the Characteristics of Common Used Refrigerants
2021-03-11
The nature of the refrigerant is directly related to the refrigeration effect of the refrigerating equipment, and even personal safety. As refrigerating men, we should understand what the commonly used refrigerants are and how to operate and manage them. 1. R22 Refrigerant The aliases of R22 refrigerant are monochlorodifluoromethane, Freon 22, F-22, refrigerant HCFC-22. Freon R22 is one of the mos...
view more