What's the difference between condenser and cooler?
2018-10-25
Today both Condenser and Cooler are very important heat exchanging components in commmercial or industrial refrigeration equipments, which are widely applied in many fields. Lots of customers who look for UAR for model selection are curious about the difference between Condenser and Cooler. So let’s make a brief introduction. 1)Phase change doesn’t occur in Cooler while it happens in Condenser. Ge...
view more
-
How to descale the water-cooled condenser
2024-04-11
How does the chiller descale the water-cooled condenser? Many refrigeration units adpot water-cooled cooling system. The inner wall of the water-cooled condenser is easy to scale. These scales will affect the heat exchange effect, resulting in an increase the condensing temperature, which will badly lower cooling capacity and increased unit power consumption. Water-cooled condensers should be regu...
view more
-
UNITED (GUANGZHOU) A / C & R CO.LTD. Muestra Fuerza de Tecnología Avanzada con Nuevos Intercambiadores de Calor en Exposición de Refrigeración China
2019-04-19
El 9 de abril de 2019, UNITED (GUANGZHOU) A / C & R CO.LTD. participó en la 30ª Exposición de Refrigeración de China, llevándose la intercambiador de calor para unidades de tipo spray y la intercambiador de calo...
view more
-
The difference between square type crossflow closed circuit cooling tower and traditional open cooling tower
2019-05-08
H.Stars Group water cooled chiller unit always need to adopt cooling tower to supply water to the cooling system . Hence, H.Stars has summarizes the difference between square type cross flow closed circuit cooling tower and traditional open cooling tower. The cooling water of the open cooling tower is directly contact with the air for heat exchange in the packing process, so the purity of the...
view more
-
Summary of the Characteristics of Common Used Refrigerants
2021-03-11
The nature of the refrigerant is directly related to the refrigeration effect of the refrigerating equipment, and even personal safety. As refrigerating men, we should understand what the commonly used refrigerants are and how to operate and manage them. 1. R22 Refrigerant The aliases of R22 refrigerant are monochlorodifluoromethane, Freon 22, F-22, refrigerant HCFC-22. Freon R22 is one of the mos...
view more
-
Analysis of 10 major failure phenomena commonly seen in refrigeration equipment maintenance
2019-07-05
1. The exhaust gas temperature of the refrigeration system is too low: The low exhaust pressure is mainly caused by the small or even stop flow of the refrigerant in the refrigeration system. The exhaust pressure is too low, although the phenomenon is manifested at the high pressure end, but the cause is mostly caused by the low pressure end. Common reasons for low exhaust pressure: 1) T...
view more
-
How to manufacture the shell and tube heat exchanger I
2019-12-20
How to manufacture the shell and tube heat exchanger I Shell and tube heat exchanger is a kind of heat transfer device, which is composed of shell, tube plate, tube bundle, baffle and cover; How is the manufacture to produce the shell and tube heat exchanger? In the manufacturing of heat exchanger, the manufacturing process of cylinder, head and other parts is the same as that of general con...
view more
-
How to manufacture the shell and tube heat exchanger II
2019-12-20
How to manufacture the shell and tube heat exchanger II 4. Machining: after checking whether the dimension (outer diameter, thickness) and material of the tube sheet meet the requirements of the drawing, the surface roughness of the machined tube sheet shall not be greater than 25 μ m, and the tube sheet plane shall be visible. 5. Tube plate hole processing: after the tube plate hole of the ...
view more
-
How to produce a coil heat exchanger
2020-04-17
As we all know, coil heat exchangers are very important part of a air cooled chiller and air source heat pumps. How does a factory produce coil heat exchangers? Below are total 9 different procedures to maintain superior quality products. 1. Material preparation (copper tube, end plate, side plate, middle support plate, short U-head, gas / liquid tube, liquid distribution tube) 2. Fin stamping (pu...
view more
-
Shell and tube heat exchanger gaskets options
2020-06-06
In the design and manufacturing process of UAR shell and tube heat exchangers, how to ensure the encapsulation of the product is a very important topic. At present, there are many seal materials available on the market, the media in the container are diversified, and the physical properties of various media vary greatly. Choosing the right sealing gasket according to the working conditions a...
view more
-
Meet in Chongqing,Meet in Refrigeration Exhibition | Hstarschiller.com
2020-09-03
The 31st International Exhibition on Refrigeration, Air Conditioning, Heating, Ventilation and Food Frozen Exhibition (abbreviated as China Refrigeration Expo 2020) will be held at Chongqing International Expo Center from August 19 to 21, 2020. At that time, Guangzhou United A/C&R Co., Ltd. will bring its self-developed all-stainless steel products, titanium tube evaporator, and H.Stars ...
view more
-
Basic requirements for structural design of low temperature heat exchanger
2020-09-09
Carbon steel and low-alloy steel heat exchangers (design temperature lower than -20℃), austenitic stainless steel heat exchangers (design temperature lower than -196℃) are low temperature heat exchangers, and the structural design should follow the following in principle. Material selection of low temperature heat exchanger: 1. Use temperature of plastic materials Polyvinyl chloride (PVC) -15℃~+80...
view more
-
The Difference of Three Types Heat Exchanger in Hot Water unit
2020-10-26
In general, tube heat exchanger in hot water unit has long life span. Shell and tube heat exchanger structure: The shell and tube heat exchanger is composed of shell, heat transfer tube bundle, tube sheet, baffle plate (baffle plate), and tube box. The shell is mostly cylindrical with a tube bundle inside, and both ends of the tube bundle are fixed on the tube plate. There are two types of heat tr...
view more
-
The Role and Characteristics of Condenser in Refrigeration System
2020-11-16
The four major components of the refrigeration system are compressor, evaporator, condenser and throttling device. The role of the condenser in the refrigeration system is mainly to cool and liquefy the gaseous refrigerant in the high temperature and high pressure state discharged from the compressor, so as to meet the requirements of the circulating use of the refrigerant in the system. The selec...
view more
-
What is a plate and shell heat exchanger | Hstarschiller.com
2020-12-07
The plate and shell heat exchanger is composed of a plate bundle composed of a plate group and a shell. It is a plasma arc welded corrugated plate group placed in the shell instead of the heat exchange tube of the original shell and tube heat exchanger. The plate group is used as the heat exchanger of the heat transfer element. The two fluid media respectively flow through the plate side and the s...
view more
-
Upgraded high-efficiency plate and shell heat exchanger advantages
2021-04-02
The plate and shell heat exchanger is composed of a plate bundle and a shell composed of a plate group. The corrugated plate group is put into the shell by plasma arc welding, instead of the heat exchange tube of the original shell and tube heat exchanger, with corrugated The plate group is used as the heat exchanger of the heat transfer element. The two fluid media respectively flow through the p...
view more
-
How to reduce the initial investment and operation cost of low-temperature chiller for chemical plants
2021-04-23
Nowadays, chemical plants always consider how to reduce the initial investment and operation cost when they need to install a low-temperature chiller system for the factory. Because low temperature refrigeration unit is a very important equipment in chemical plant, which plays an important role in safety production. The initial investment of low-temperature refrigeration unit is large, and i...
view more
-
H.Stars Group developed a series of new refrigerant equipment with low GWP for carbon reduction and energy saving in 2021
2021-12-07
According to the news on December 23, Chemours announced that from January 1, 2020, they will stop supplying high-GWP R404A and R507A refrigerants to the European Union. At the time of this announcement, Europe is preparing to implement a ban on high-GWP refrigerants in accordance with the European F-gas regulations (517/2014) implemented on January 1. According to the European F-gas phase-out sch...
view more