-
What is the application for industrial chillers
2020-09-15
Industrial Water Chillers are used in many Industries The cooling pump of industrial chilled water or other liquid is through process or laboratory equipment. Industrial water chillers are used to control the products, mechanisms and factory machinery industries. The industrial water chiller can be centralized; each unit cooling meets a variety of needs, or dispersed in each application or device,...
view more
-
UNITED (GUANGZHOU) A / C & R CO.LTD. Muestra Fuerza de Tecnología Avanzada con Nuevos Intercambiadores de Calor en Exposición de Refrigeración China
2019-04-19
El 9 de abril de 2019, UNITED (GUANGZHOU) A / C & R CO.LTD. participó en la 30ª Exposición de Refrigeración de China, llevándose la intercambiador de calor para unidades de tipo spray y la intercambiador de calo...
view more
-
Pharmaceutical Factories, by Using These Ways, Can Clean the Air Conditioning System to Save 40% of the Operating Costs.
2019-05-21
Pharmaceutical factories need to meet the relevant requirements of GMP in the production process, and the temperature, humidity and cleanliness must be controlled within a certain range. Under normal circumstances, when there is no special requirement, the temperature should be controlled between 18 ° C ~ 26 ° C; the relative humidity is controlled at 45% ~ 65%. The clean area of pharmaceutical fa...
view more
-
The three major drawbacks of the refrigeration equipment industry urgently need to be solved
2019-05-30
Refrigeration equipment is now widely used in various fields, and different industry requirements for equipment specifications are also different. With the expansion of various industries, the requirements and goals for refrigeration equipment are higher and higher. From the current situation, China's refrigeration industry still has many shortcomings, and its most obvious performance is the follo...
view more
-
The Reason Why the Temperature of Condensers of Water Cooled Chillers are Abnormally High
2019-06-28
Why are the temperature of condensers of water cooled chiller are abnormally high? The water-cooled condenser we mention here is mainly used in water-cooled chillers. Its function is to use the high-temperature refrigerant vapor condenser discharged from the compressor as a liquid refrigerant, which is an important part of the refrigeration system to release heat to the surrounding envir...
view more
-
Analysis of 10 major failure phenomena commonly seen in refrigeration equipment maintenance
2019-07-05
1. The exhaust gas temperature of the refrigeration system is too low: The low exhaust pressure is mainly caused by the small or even stop flow of the refrigerant in the refrigeration system. The exhaust pressure is too low, although the phenomenon is manifested at the high pressure end, but the cause is mostly caused by the low pressure end. Common reasons for low exhaust pressure: 1) T...
view more
-
The Solutions of Common Low Pressure for Chillers
2019-07-26
There are many factors that cause low-pressure failure of cold water (freezer) machines, and we only list some of them today. It can be roughly divided into the following categories (from easy to difficult sequence) system leakage, system blockage, and evaporator blockage. Important: The "Reset button" on the pressure controller must be pressed after each fault point has been processed. Common low...
view more
-
Magnetic Oil Free Centrifugal Chiller Advantages
2019-08-26
With the rapid development of the times and economy, energy conservation, environmental protection, and emission reduction have become an indispensable new era mission. For a long time, the problems of “high energy consumption and secondary pollution” of central air-conditioning have brought great burdens to various industries. In the process of product operation, oil pollution, greenhouse ef...
view more
-
How can pharmaceutical air conditioning systems reduce operating costs by 40%
2019-08-30
Pharmaceutical factories need to meet GMP requirements in the production process, and the temperature, humidity and cleanliness should be controlled within a certain range. Under general circumstances, the temperature should be controlled at 18℃~26℃, the relative humidity should be controlled at 45%~65%, the pharmaceutical factory clean area is divided into ABCD level. The C and D level of the wor...
view more
-
How to manufacture the shell and tube heat exchanger II
2019-12-20
How to manufacture the shell and tube heat exchanger II 4. Machining: after checking whether the dimension (outer diameter, thickness) and material of the tube sheet meet the requirements of the drawing, the surface roughness of the machined tube sheet shall not be greater than 25 μ m, and the tube sheet plane shall be visible. 5. Tube plate hole processing: after the tube plate hole of the ...
view more
-
Shell and tube heat exchanger gaskets options
2020-06-06
In the design and manufacturing process of UAR shell and tube heat exchangers, how to ensure the encapsulation of the product is a very important topic. At present, there are many seal materials available on the market, the media in the container are diversified, and the physical properties of various media vary greatly. Choosing the right sealing gasket according to the working conditions a...
view more
-
Tips for seasonal water chiller system shutdown in winter
2021-03-12
Introduction: Winter is coming, and the ambient temperature is about to drop below zero. This will cause great damage to the chillers, water pumps, cooling towers, terminals and other equipment. In order to ensure that chillers work normally during winter, the chiller has to survive in the low temperature environment, because it will cause a great loss to users if the unit is not maintained with p...
view more
-
How does H.Stars produce water-cooled high-efficiency Chiller for Pharmaceutical Factory
2022-09-23
Today, H.Stars would like to introduce to you a batch of high-efficiency chillers that will be used in a pharmaceutical factory as cooling equipment. They only use R134 environmentally friendly refrigerant, and the COP of the whole machine is as high as 5.6. It protects the environment and saves energy. It is a real work of conscience. H.Stars has served more than 1,000 pharmaceutical companies ar...
view more
-
What Size Heat Pump Do I Need
2023-07-12
Choosing the right size heat pump is essential for optimal performance and energy efficiency in industrial applications. As an industrial user in the HVAC industry, it's crucial to understand the benefits of correctly sizing a heat pump, the problems associated with undersized and oversized units, and why relying on rules of thumb and online calculators can lead to inaccurate results. In this blog...
view more
-
What is Glycol Chiller and Why Glycol is Used for Cooling
2023-07-27
Introduction: In the industrial cooling industry, glycol chillers play a vital role in maintaining optimal temperatures for various applications. Understanding why glycol is used for cooling, how a glycol system works, and how to choose the right capacity of a glycol chiller is essential for users in need of industrial cooling solutions. In this blog post, we will explore these three key aspects r...
view more
-
How to Choose the Right Glycol Chiller
2023-08-04
Introduction: When it comes to industrial cooling needs, selecting the right glycol chiller is crucial for optimal performance and efficiency. Whether you require a glycol chiller for a specific project or application, understanding its uses, choosing the appropriate capacity, and sizing it correctly are essential factors to consider. In this blog post, we will explore these three key aspects to g...
view more
-
Optimal Selection of Refrigerants for Cold Storage: Navigating Environmental Concerns
2024-01-04
As global attention to environmental protection and climate change continues to rise, the choice of refrigerants for cold storage not only affects efficiency and cost-effectiveness but is also influenced by international environmental regulations. Agreements like the Paris Agreement and the Montreal Protocol, with the Kigali Amendment, impose new requirements on refrigerant usage. This article wil...
view more
-
Cleanroom Design Calculations – Unveiling the Secrets of Air Supply Calculations
2024-01-16
The calculation of air supply in a cleanroom differs from that of a general HVAC system. HVAC systems determine air supply based on calculated thermal and humidity loads, considering an economical air supply temperature difference to eliminate excess heat and moisture. In contrast, cleanroom air supply is generally calculated independent of thermal and humidity loads. Instead, it is based on the r...
view more